Reviews Voltage Range
ARCELI Boost Buck Converter,Communication Constant DC - DC Voltage Current Step-Down Power Supply Module Buck Voltage Converter Voltmeter 50V 5ADPS5005+USB+BT
- buck voltage converter input voltage range DC 6-55V, output voltage range 0-50V, output current range 0-5A, output power range 0-250W, output voltage resolution 0.01V, output current resolution: 0.001A..
- Wireless & Wire Connection: it can connect with computer by Bluetooth, in the distance range of 5 meters.
- or can connect by the USB communication board. User can remote monitor, voltage setting and current setting can be operated quickly..
- Quick Operation: it is easy to operate converter with this, you can do voltage setting and current setting as quickly as possible.
- you can also set it to cut off output when over voltage, over current and over power..
- LCD Display: Built with color LCD display, it will be convenient for you to review preset voltage, input voltage, output voltage, preset current, output current, output power and brightness of LCD..
- Package Including: 1x DC adjustable constant voltage power supply converter.
Check StockJuried Engineering LM2903P LM2903 Dual Differential Comparator Automotive Grade Breadboard-Friendly IC DIP-8 (1 Piece)
- The LM2903P devices consist of two independent voltage comparators that are designed to operate from a single power supply over a wide range of voltages.
- Single-supply or dual supplies Wide range of supply voltage Maximum rating: 2 V to 36 V.
- Low supply-current independent of supply voltage: 200 µA per comparator, Output compatible with TTL, MOS, and CMOS.
- Common-mode input voltage range Includes Ground, Low output saturation voltage.
- Differential input voltage range equal to maximum-rated supply voltage: ±36 V.
Check StockSWM
- Technical Information - Frequency Range - 2000 kHz to 2150 MHz.
- Input Voltage Range - 100 V AC to 120 V AC.
Check StockComparator Dual177;18V/36V 8-Pin SO N T/R
- Wide range of supply voltage Maximum rating: 2 V to 36 V, Low input bias current, Low output saturation voltage.
- Low supply-current independent of supply voltage: 200 µA per comparator, Low input offset voltage.
- Common-mode input voltage range Includes Ground, Output compatible with TTL, MOS, and CMOS.
- Differential input voltage range equal to maximum-rated supply voltage: ±36 V, Example Applications: Vacuum robot, Single phase UPS, Server PSU, Cordless power tool, Wireless Infrastructure, Appliances, Building Automation, Factory automation & control, Motor drives, Infotainment & cluster.
Check StockJuried Engineering LM319N LM319 High Speed Dual Comparator Breadboard-Friendly (Pack of 5)
- Four independent voltage comparators that are designed to operate from a single power supply over a wide range of voltages.
- Wide Supply Ranges Single Supply: 2 V to 36 V, Dual Supplies: ±1 V to ±18 V, Differential Input Voltage Range Equal to Maximum-Rated Supply Voltage: ±36 V, Low Input Offset Current: 3 nA (Typical).
- Low Supply-Current Drain Independent of Supply Voltage: 0.8 mA (Typical), Low Output Saturation Voltage, Common-Mode Input Voltage Range Includes Ground.
- Low Input Bias Current: 25 nA (Typical), Low Input Offset Voltage: 2 mV (Typical), Low Output Saturation Voltage.
- Example Applications: Industrial, Automotive: Infotainment and Clusters, Body Control Modules, Power Supervision, Oscillators, Peak Detectors, Logic, Voltage Translation.
Check StockTexas Instruments LM311P LM311 Differential Comparator With Strobes DIP8 5 Pack
- Wide range of supply voltage Maximum rating: 2 V to 36 V, Low input bias current, Low output saturation voltage.
- Low supply-current independent of supply voltage: 200 µA per comparator, Low input offset voltage.
- Common-mode input voltage range Includes Ground, Output compatible with TTL, MOS, and CMOS.
- Differential input voltage range equal to maximum-rated supply voltage: ±36 V, Example Applications: Vacuum robot, Single phase UPS, Server PSU, Cordless power tool, Wireless Infrastructure, Appliances, Building Automation, Factory automation & control, Motor drives, Infotainment & cluster.
Check StockACS712 Hall Effect Current Sensor Module 5A 20A 30A Range + Voltage Sensor Module DC0-25V Voltage Tester Terminal Sensor for Arduino
- 【Perfect Combination】Using this product can measure both voltage and current, very suitable for DIY electronic design projects..
- 【Package Included】1pcs x 30A,1pcs x 20A, 1pcs x 5A ACS712 Current Sensor Module, and 1pcs x Voltage Sensor Module DC0-25V Voltage Tester Terminal....
- 【Current Sensor Module】Chip: ACS712ELC-05A,Measuring range: ±5 amps, corresponding Analog output:185mV/A.--- ACS712ELC-20A,Measuring range:....
- 【Voltage Sensor Module】Voltage input range: DC0-25V.
- 【Pls Note】: ACS712 is based on the principle of Hall detection, please avoid the influence of magnetic field when using it!.
Check StockJuried Engineering LM393P LM393 IC Dual Differential Comparator & 8-Pin DIP Sockets with Machined Contact Pins Breadboard-Friendly (Pack of 10)
- Four independent voltage comparators that are designed to operate from a single power supply over a wide range of voltages.
- Wide Supply Ranges Single Supply: 2 V to 36 V, Dual Supplies: ±1 V to ±18 V, Differential Input Voltage Range Equal to Maximum-Rated Supply Voltage: ±36 V, Low Input Offset Current: 3 nA (Typical).
- Low Supply-Current Drain Independent of Supply Voltage: 0.8 mA (Typical), Low Output Saturation Voltage, Common-Mode Input Voltage Range Includes Ground.
- Low Input Bias Current: 25 nA (Typical), Low Input Offset Voltage: 2 mV (Typical), Low Output Saturation Voltage.
- Example Applications: Industrial, Automotive: Infotainment and Clusters, Body Control Modules, Power Supervision, Oscillators, Peak Detectors, Logic, Voltage Translation.
Check StockDEVMO DP20V2A Constant Voltage Constant Current Programmable Control Step-Down Supply Power Module
- The constant voltage and constant current programmable control power supply module is cabinet and delicate, and it put the collection of analog integration and digital control functions in one..
- Its adjustable output voltage range is 0-20.0V, step by 0.1V. Its adjustable output current range is 0-2.00A, step by 0.01A..
- The constant voltage and constant current programmable control power supply module is cabinet and delicate, and it put the collection of analog integration and digital control functions in one. Its adjustable output voltage range is 0-20.0V, step by 0.1V. Its adjustable output current range is 0-2.00A, step by 0.01A. Boot voltages can be stored freely and the model has two groups of quick storage voltage. Compared with the traditional analog power supply, it is more convenient to quickly extrac.
- Adjusting preset voltage:Pressing SET button, page down to U-SET, press the codding potentiometer, then enter toadjustnumeric value. Press codding potentiometer in turn to choose the numeric value you want to adjust. Turn codding potentiometer to adjust the numeric value. If you want toexit adjusting voltage, press shortly SET. In the process of adjusting preset voltage, if you open output voltage mode by pressing the ON/OFF, the output voltage wi....
Check StockJuried Engineering LM393P IC Dual Differential Comparator & 8-Pin DIP Sockets with Machined Contact Pins Breadboard-Friendly (Pack of 1)
- Wide range of supply voltage Maximum rating: 2 V to 36 V, Low input bias current, Low output saturation voltage.
- Low supply-current independent of supply voltage: 200 µA per comparator, Low input offset voltage.
- Common-mode input voltage range Includes Ground, Output compatible with TTL, MOS, and CMOS.
- Differential input voltage range equal to maximum-rated supply voltage: ±36 V, Example Applications: Vacuum robot, Single phase UPS, Server PSU, Cordless power tool, Wireless Infrastructure, Appliances, Building Automation, Factory automation & control, Motor drives, Infotainment & cluster.
Check StockAT&T (Formerly DIRECTV) 21 Volt Power Inserter for All DIRECTV SWM LNBs (PI21)
- Technical Information - Frequency Range - 2000 kHz to 2150 MHz.
- Input Voltage Range - 100 V AC to 120 V AC.
Check StockTexas Instruments LM358P Low Power Dual OP Amplifier, General Purpose, 8-Pin, -16-32 Volt, 9.81 mm L x 6.35 mm W x 4.57 mm H (Pack of 15)
- Four independent voltage comparators that are designed to operate from a single power supply over a wide range of voltages.
- Wide Supply Ranges Single Supply: 2 V to 36 V, Dual Supplies: ±1 V to ±18 V, Differential Input Voltage Range Equal to Maximum-Rated Supply Voltage: ±36 V, Low Input Offset Current: 3 nA (Typical).
- Low Supply-Current Drain Independent of Supply Voltage: 0.8 mA (Typical), Low Output Saturation Voltage, Common-Mode Input Voltage Range Includes Ground.
- Low Input Bias Current: 25 nA (Typical), Low Input Offset Voltage: 2 mV (Typical), Low Output Saturation Voltage.
- Example Applications: Industrial, Automotive: Infotainment and Clusters, Body Control Modules, Power Supervision, Oscillators, Peak Detectors, Logic, Voltage Translation.
Check StockNon-Contact Voltage Tester Pen - Dual Range AC Voltage Tester 12V/48V-1000V, Live/Null Wire Circuit Detection Tester Breakpoint Finder Electrical Outlet Voltage Detector, Measure AC Circuit Tester
- Safety and Security: Non-contact voltage tester has passed the CE CAT III 1000V CAT IV 600V test certification. When the ac electrical tester pen detects a voltage, the probe will flash red and beep, the higher the detected voltage, or the closer it is to the voltage source, the dual range voltage detector will beep at a higher frequency. The ac socket tester detects low voltage and neutral and triggers a yellow flashing light, and detects high voltage and live wire triggers a red flashing light.
- Non-Contact: The ac circuit tester uses a non-contact method to measure voltage, with an NCV induction probe for detecting ac voltage, you only need to place the tip of an electric circuit detector near an outlet or power cord to detect the presence of voltage.The dual range circuit voltage tester is a safe double insulation, you don't have to worry about being shocked, voltage detector tool is very safe, and it is an ideal device to help determine the neutral or live line and breakpoint testing.
- Dual Range: The electrical current tester detects standard voltage and low voltage ranges (12-1000V AC / 48-1000V AC), making the measurement more flexible and accurate. NCV sensitivity is automatically adjusted from low to high, low sensitivity can detect doorbells, ....
Check Stock