Reviews T type Thermocouple

Instrukart Dry Block High Temperature Calibrator AI-DBC 650 for Calibration Labs Pharmaceutical divisions Thermal Plants divisions Along with Calibration Certificate

  • Accuracy: ±0.6°C, Bath Stability: ±0.5°C.
  • Measuring Functions: J Type Thermocouple, K Type Thermocouple, T Type Thermocouple, R Type Thermocouple, S Type Thermocouple, N Type Thermocouple, MA, MV, Volts, Ohms, RTD (Pt 100).
  • Temperature Steps: 50°C, 150°C, 300°C, 450°C, 600°C.
  • Switch Test: Continuity check with OPEN / CLOSE indication.
  • Transmitter Supply: 24V DC ± 10% (Loop Powered).
  • Power Supply: 230V AC ± 5% / 50Hz, 500 W for 350UTC.
  • Supply Scope: Instrument, Power Cable, Carrying Case, Test Lead(2 & 3 Wire), Insertion Tube, Insertion Tool,Spare Fuses: 6A x 2nos User Manual, Calibration Certificate.
Check Stock

Fluke 51 II Single Input Digital Thermometer

  • Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
  • Measures temperatures in celsius, fahrenheit, or kelvin via a type k, type j, type t, or type e thermocouple probe.
  • Includes a type k bead thermocouple probe with a 40" cable that measures from minus 40 to +260 degrees c ( minus 40 to +500 degrees f).
  • Provides the relative time of minimum, maximum, and average temperature measurements for monitoring.
  • Conforms to nist standards for compliance with regulations.
Check Stock

Fluke - FLUKE-52-2 60HZ 52-2 60HZ Dual Input Digital Thermometer

  • Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
  • Measures temperatures in Celsius, Fahrenheit, or Kelvin via a Type K, Type J, Type T, or Type E thermocouple probe.
  • Includes a Type K bead thermocouple probe with a 40" cable that measures from -40 to +260 degrees C (-40 to +500 degrees F).
  • Provides the relative time of minimum, maximum, and average temperature measurements for monitoring.
  • Conforms to NIST standards for compliance with regulations.
Check Stock

ennoLogic Volt mA Thermocouple Loop Process Calibrator eC370T - 0-20V and 4-20mA Simulator – Portable Millivolt mA and Temperature Signal Generator and Meter for Transmitters Current Loops PLC

  • VERSATILE AND ACCURATE VOLT MA THERMOCOUPLE CALIBRATOR: Signal generator, simulator and volt / mA meter for calibrating, testing and repairing milliamp loops, thermocouples, PLC, temperature control and HVAC systems. Easily generate precise test signals for current and voltage devices (mA, mV, V, Celsius and Fahrenheit ranges)..
  • NUMERIC KEYPAD for ease and flexibility in setting output signals configuring options. HOTKEY programming for each numeric key (long-press immediately outputs user-configured voltage, current or temperature signal). RAMP AND LADDER OUTPUT FUNCTIONS can be custom configured. BUILT-IN 24V LOOP SUPPLY lets you power and read a device or transmitter without needing another multimeter. This greatly simplifies testing 2-wire current loops..
  • MEASURE VOLTAGE OUTPUT SIGNALS from process devices and sensors with two input ranges of 0-100mV (0.01mV resolution, 0.06% accuracy) and 0-20V (1mV resolution, 0.08% accuracy). MEASURE CURRENT TRANSMITTERS within a range of 0 to 24mA with 0.001mA resolution and 0.08% accuracy. MEASURE THERMOCOUPLE TEMPERATURES within a range of -250°C to +1800°C and resolution of ±0.7°C to ±2°C (range and resolution depends on thermocouple type, supported are type K, J, E, T, N, S, R, and B.).
Check Stock

Fluke 53-2 Single Input Digital Thermometer with USB Recording, 3 AA Battery, -418 to 3212 Degree F Range, 60 Hz Noise Rejection

  • Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
  • Measures temperatures in Celsius, Fahrenheit, or Kelvin via a Type K, Type J, Type T, Type E, Type N, Type R, or Type S thermocouple probe.
  • Includes a Type K bead thermocouple probe with a 40" cable that measures from -40 to +260 degrees C (-40 to +500 degrees F).
  • Stores up to 500 points of data for analysis and monitoring.
  • Conforms to NIST standards for compliance with regulations.
Check Stock

Fluke 52-2 Dual Input Digital Thermometer, 3 AA Battery, -418 to 2501 Degree F Range, 60 Hz Noise Rejection

  • Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
  • Measures temperatures in Celsius, Fahrenheit, or Kelvin via a Type K, Type J, Type T, or Type E thermocouple probe.
  • Includes a Type K bead thermocouple probe with a 40" cable that measures from -40 to +260 degrees C (-40 to +500 degrees F).
  • Provides the relative time of minimum, maximum, and average temperature measurements for monitoring.
  • Conforms to NIST standards for compliance with regulations.
Check Stock

REED Instruments R2800 Temperature Simulator (Thermocouple and RTD)

  • Source 8 thermocouple types, including R, S, B, E, K, J, T, N.
  • and 7 RTD types, including Pt 10 (385), Pt100 (385), Pt200 (385), Pt500 (385), Pt1000 (385), Cu10, Cu50.
  • Includes test leads, alligator clips, thermocouple adapter, protective holster and batteries.
Check Stock

K Type Thermocouple Temperature Thermocouple Sensor Temperature Detector Temperature Gauge with M4 Thread for 3D Printer Temperature Sensor

  • Type K (chromel–alumel) is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.[10] It is inexpensive, and a wide variety of probes are available in its −200 °C to +1350 °C (−330 °F to +2460 °F) range. Type K was specified at a time when metallurgy was less advanced than it is today, and consequently characteristics may vary considerably between samples. One of the constituent metals, nickel, is magnetic.
  • a characteristic of thermocouples made with magnetic.
  • They operate very well in oxidizing atmospheres. If, however, a mostly reducing atmosphere (such as hydrogen with a small amount of oxygen) comes into contact with the wires, the chromium in the chromel alloy oxidizes. This reduces the emf output, and the thermocouple reads low. This phenomenon is known as green rot, due to the color of the affected alloy. Although not always distinctively green, the chromel wire will develop a mottled silvery skin and become magnetic. An easy way to check for t.
  • Hydrogen in the atmosphere is the usual cause of green rot. At high temperatures, it can diffuse through solid metals or an intact metal thermowell. Even a sheath of magnesium oxide insulating the thermocouple will not keep the hydrogen out..
Check Stock

Montague OVEN THERMOCOUPLE 48\ 1036-7

  • K-type thermocouple connector with real chromel alumel contacts.
  • Miniature or mini k-type connector dimensions.
  • Works with all k-type thermocouple wires and extension wires.
  • Set of 10 male mini thermocouple connector plugs.
  • Compatible with thermocouple plugs from other manufacturers.
Check Stock

Thermco ACC310DLSDIG Laboratory Long Stem Digital Thermometer, 12\ Stem Length, -50 to 300°C Range, +/-1.0°C Accuracy

  • High Temperature K-type Thermocouple Thermometer Set with Stainless Steel Probe.
  • K-type thermocouple wire with Standard Accuracy: +/- 2.2 °C or +/- .75%.
  • 5 ft (155 cm) long thermocouple cable with braided stainless steel cover, mini thermocouple plug made from chromel / alumel.
  • Temperature measurement range: -328 to 932 °F (-200 to 500 °C), short term 1472 °F (800 °C).
  • Grounded K-type Thermocouple junction for fast measurements, 1x 9V battery included.
Check Stock

Mastech MS6514 Dual Channel Digital Thermometer Temperature logger Tester USB Interface 1000 data

  • Apply to the J / K / T / E / R / S / N type thermocouple..
  • Thermocouple deviation to compensate for..
  • Automatic and manual storage Data(1000)..
Check Stock

GBC Document Camera, Discovery 3000 (DCV10004)

  • pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F) and Overload display alert when input exceeds measurement range pyrometer. Thermocouple Temperature range: -50°C to 1000°C ( -58°F to 1832°F).
  • Designed for use with K-type thermocouples and Selection between Celsius and Fahrenheit.
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Includes 2 Thermocouples ( One 3" K type temperature probe (-58 – 752 °F) and one Kiln Heavy duty K type Thermocouple ( -58°F to 1832°F) and Digital Pyrometer, 9V battery and Manual.
  • Thermocouple Measurement range: 32 - 1832 °F (0 - 1000 °C) Thermocouple Type: K Type Cable length : 3 ft Sensing tip length: 6" (150mm) Stainless Steel Sensing tip diameter: 0.19" (5mm) Thread width : 5/16" (M8) Internal Insulation: Fiber Glass External shielding: Metal Shield (Stainless steel braided).
Check Stock

PIE 525B Automated T/C & RTD Calibrator 12 RTD & 14 T/C types

  • Automated RTD and Thermocouple Calibrator. Comes with rubber boot, hands free carrying case, test leads and NIST cert..
  • Easy to use With the PIE 525B you can check and calibrate all your thermocouple and RTD instruments and measure temperature sensors..
  • Take it into the shop, plant or field Carry it without worry - it comes protected with a rubber boot and rugged, low profile switches. Easy to operate even in the dark areas of the plant with the backlit display..
  • Calibrate thermocouple instruments to 0.1 & 0.01 degrees-F & degrees-C The PIE 525B works with the thermocouples you use including types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II). Or calibrate from -13.0000 to +80.0000 mV..
  • Calibrate RTD instruments to 0.1 & 0.01 degrees-F & degrees-C Stop carrying around a decade box and RTD resistance tables. The 525B works with the RTDs you use including Platinum 10, 50, 100, 200, 500 & 1000 Ohm (alpha = 3850), Platinum 100 Ohm (alpha = 3902, 3916, 3926), Copper 10 & 50 Ohm, and Nickel 120 Ohm. Or calibrate from 0.000 to 400.000 and 0.00 to 4000.00 Ohms..
Check Stock