Reviews Murray Amp Main Breaker
Siemens ECSBPK01 Generator Standby Power Mechanical Interlock
- Main breaker is double pole QP breaker 15-125 Amp.
- Standby power breaker is a QP or MP type.
Check StockSiemens ECSBPK03 Generator Standby Power Mechanical Interlock
- Ensures the main breaker within a panel is forced to the off position when standby power is on.
- For use on Siemens or Murray panels that are 150, 200, or 225 amp, ultimate or rock solid type.
- Standby power breaker must be a QP or MP double pole breaker.
Check StockSiemens ECSBPK07 Standby Power Mechanical Interlock for Use on Meter Combinations
- Main breaker is a QN, QNR, MD-T, or MD-TR.
- Standby power breaker must be a QP or MP-T double pole breaker.
Check StockMP120 20-Amp Single Pole Type MP-T Circuit Breaker
- Single pole, 20 Amp, 120V type MP-T Circuit Breaker.
- Murray type MP-T circuit breakers provide easy plug-in connections in Murray enclosures and the time saving insta-wire feature.
- Compatible with Murray rock solid load centers.
- Use for overload and short-circuit protection of your electrical system.
Check StockChallenger 2P 30A Breaker - A230
- Replacement Challenger MH250 Type A circuit breaker manufactured new by Connecticut Electric.
- For use in Challenger Type A circuit breaker panels.
- Intertek ETL Listing to UL Standard 489-Molded case circuit breakers.
- 120/240 VAC 2 Pole breaker 1" thin type breakers.
- May also be branded: Murray, Crouse-Hinds, or Sylvania.
Check StockSiemens Q22025CT 25-Amp Double Pole Two 20-Amp Single Pole Circuit Breaker
- Single pole, 25 Amp, 120V type MP-T Circuit Breaker.
- Murray type MP-T circuit breakers provide easy plug-in connections in Murray enclosures and the time saving insta-wire feature.
- Compatible with Murray rock solid load centers.
- Use for overload and short-circuit protection of your electrical system.
Check StockConnecticut Electric UBITB-A220 New Challenger MH220 Type-A Replacement. Two Pole 20 Amp Clip Circuit Breaker Manufactured
- Replacement Challenger MH220 Type A circuit breaker manufactured new by Connecticut Electric.
- For use in Challenger Type A circuit breaker panels.
- Intertek ETL Listing to UL Standard 489-Molded case circuit breakers.
- 120/240 VAC 2 Pole breaker 1" thin type breakers.
- May also be branded: Murray, Crouse-Hinds, or Sylvania.
- Type UBITBA for use in Challenger/T&B load centers.
Check StockSquare D - QOM2200VH Bolt On Circuit Breaker, 200A, 2 Pole, Qom, Color
- QOM 200 Amp 22k AIR QOM2 Frame Size main circuit breaker for QO and Homeline Load Centers.
- QOM2 frame size main circuit breaker that is field-installable.
- Protect a breaker panel in a QO or Homeline 200 - 225 Amp main lug load center or CSED with this QOM2 frame size main breaker.
Check StockConnecticut Electric UBITBA120L-New Challenger MH120-L Type A Replacement One Pole Left Clip Circuit Breaker.
- Replacement Challenger MH120-L Type A circuit breaker manufactured new by Connecticut Electric.
- For use in Challenger Type A circuit breaker panels.
- Intertek ETL Listing to UL Standard 489-Molded case circuit breakers.
- 120 VAC 1 Pole breaker 1/2" thin type breaker.
- May also be branded: Murray, Crouse-Hinds, or Sylvania.
Check StockSquare D by Schneider Electric QOM125VHCP QOM1 Frame Size 125-Amp Main Breaker for QO
- QOM 125 Amp 22k AIR QOM1 Frame Size main circuit breaker for QO or Homeline Load Centers.
- QOM1 frame size main circuit breaker that is field-installable.
- Protect a breaker panel in a QO or Homeline 125 Amp main lug load center or CSED with this QOM1 frame size main breaker.
Check StockConnecticut Electric UBITBA115R New Challenger MH115-R Type-A Replacement. One Pole 15 Amp Right Clip Circuit Breaker, Black
- Replacement Challenger MH115-R Type A circuit breaker manufactured new by Connecticut Electric.
- For use in Challenger Type A circuit breaker panels.
- Intertek ETL Listing to UL Standard 489-Molded case circuit breakers.
- 120 VAC 1 Pole breaker 1/2" thin type breaker.
- May also be branded: Murray, Crouse-Hinds, or Sylvania.
Check StockConnecticut Electric UBITBA240 New Challenger MH240 Type A Replacement, Two Pole 40 Amp Clip Circuit Breaker
- Replacement Challenger MH240 Type A circuit breaker manufactured new by Connecticut Electric.
- For use in Challenger Type A circuit breaker panels.
- Intertek ETL Listing to UL Standard 489-Molded case circuit breakers.
- 120/240 VAC 2 Pole breaker 1" thin type breakers.
- May also be branded: Murray, Crouse-Hinds, or Sylvania.
Check StockSquare D - QOM2150VH QO 150-Amp QOM2 Frame Size Main Circuit Breaker for QO and Homeline Load Centers
- QOM 150 Amp 22k AIR QOM2 Frame Size main circuit breaker for QO and Homeline Load Centers.
- QOM2 frame size main circuit breaker that is field-installable.
- Protect a breaker panel in a QO or Homeline 150 - 225 Amp main lug load center or CSED with this QOM2 frame size main breaker.
Check Stock