Reviews Lc1 d Ac Contactors
Coleman - 40 Amp 1 Pole 24v Coil Replacement Contactor C140A
- BUNDLE CONTENT: 5 ITEMS – Two (2) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated....
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp,....
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specifications adopted by European....
Check StockElectrodepot 40 Amp 12 Pole (4 Pole x 3) Normally Open, 110-120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with 8\ DIN Rail and 2 Number 10 Screws
- BUNDLE CONTENT: 6 ITEMS – Three (3) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated 35mm x 200mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificat....
Check StockElectrodepot 40 Amp 8 Pole (4 Pole x 2) Normally Open, 110/120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with DIN Rail, 35 x 150 mm and 2#10 Screws
- BUNDLE CONTENT: 5 ITEMS – Two (2) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated 35mm x 150mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificatio....
Check StockElectrodepot 60 Amp 4 Pole Normally Open Contactor 110-120V Coil Motor Load 40A Lighting 63A Bundle with Slotted Steel Zinc Plated DIN Rail 35 mm x 6 in – 1 Piece with 2#10 Screws
- BUNDLE CONTENT: 4 ITEMS – One (1) 40A Contactor, one (1) compatible Slotted Steel Zinc Plated DIN Rail and two (2) drive stainless steel truss head....
- APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp,....
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specifications adopted by European....
Check StockLennox - 40 Amp 1 Pole 24v Coil Replacement Contactor C140A
- 40 FLA Amp Rating - 1 Pole - 24 Volt Coil. Replaces Most 2 Pole Contactors Rated at 20 Amps, 25 Amps, 30 Amps, 35 Amps, or 40 Amps on Air Conditioners....
- Can be used for virtually all single pole ac contactor replacements Carrier-Bryant-Payne-Goodman-Amana-Janitrol-Rheem Ruud Weatherking-Lennox,....
- Base assembly is made from high performance Bulk (Dough) molding compounds.
Check StockTrane • 40 Amp 1 Pole 24v Coil Packard Replacement Contactor C140A
- 200K cycles UL testing approval for Dp contactor.
- Replace SIEMENS 45 series dp contactor 1 pole 40FLA 24V coil.
- UL,CUL CSA, SEV S+, CE Approved AC contactor.All our DP contactors series meet the ARI Standard 780/790-1997 and UL508 standard.
- Replacement parts number: 8910DP41V14, 3100-15Q19, C25ANF140T, 45GG10AJA,HCCY1XQ04GG, C140A, DP40241..
Check StockNEW TeSys LRD thermal overload relays LR-D16 LRD16 9-13A Class 10A
- Class 10 Ambient Compensated Overload with Phase Loss Protection..
- New Aftermarket Replacement for Telemecanique Overload Relay including a 1 year warranty..
- "12-18A Adjustable Overload Mounts to NC1- D12, D18, D25 or D32 Contactor".
- Series LR overload relays are intended and UL recognized for use with US Breaker NC1D contactors..
- Telemecanique parts are provided to assist selection. Select products according to each applicaion..
Check StockMcdonnell & Miller Flow Switch, 1 in SPDT FS4-3
- Working Temperature: -10 to 50 Degrees Celsius.
- Tip: The max switching current of the contact is 0.5A. Generally, it should be used together with small relay. Excessive current will burn the contact. Cannot directly control AC contactors, solenoid valves, alarms, pumps, and various lights..
- What is in the package: 2pcs M16 Water Level Sensor.
Check StockNR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A)
- 10.0 - 16.0 Amp, IEC, Overload Relay, Type: Thermal Bi-Metallic. Trip Class 10. Selectable Manual or Automatic Reset. For use with XT Series, Frame D Contactors..
Check StockANTOBLE PC140A C140A Contactor Single One 1 Pole 40 Amps 24 Volts A/C Air Conditioner
- 40 FLA Amp Rating - 1 Pole - 24 Volt Coil. Replaces Most 2 Pole Contactors Rated at 20 Amps, 25 Amps, 30 Amps, 35 Amps, or 40 Amps on Air Conditioners....
- Enclosed Contacts and Encapsulated 24 Volt Coil.
- Heavy Lug Terminals and Push-Ons for High Voltage Connections.
- Can be used for virtually all single pole ac contactor replacements Carrier-Bryant-Payne-Goodman-Amana-Janitrol-Rheem Ruud Weatherking-Lennox,....
Check StockArmy Universe Olive Drab Combat H Style LC-1 Military Suspenders Load Bearing Harness Backpack Straps
- H STYLE LC1 SUSPENDERS: Lightweight regulation construction with top-quality craftsmanship for maximum durability and comfort. Made from rugged polyester construction with metal hardware clips..
- DESIGNED FOR COMFORT: The H-style combat suspenders design compensates for weight distribution and load shifts, relieving pressure on your hips and pants..
- FULLY ADJUSTABLE: Comfortable padded shoulder straps. D ring on each strap. Fully adjustable shoulder straps to almost any size..
- ATTACH IT EASILY: Comes with 4 metal clips that you can use to attach to your equipment belt, backpack, butt pack and more!.
- RUGGED CONSTRUCTION: Made to military specifications, this rugged load bearing harness is a must-have for anyone who needs to carry heavy equipment for extended periods of time..
Check StockElectrodepot 40 Amp 4 Pole Normally Closed Contactor, 110-120V Coil, Motor Load 20A, Lighting 40A Bundle with Slotted Steel Zinc Plated DIN Rail, 35 mm x 6 in – 1 Piece with 2 Number 10 Screws
- ...power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 85 x 45 x 92 mm / 3.4'' x 1.7'' x 3.6'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specifications adopted by European (EN) and international (IEC) standards. Standard width 34.9mm (1.375”) length 152.40mm (6”) and thickness 5mm (0.2”).
Check StockEaton/Cutler Hammer C25BNB230A Contactor, 2-Pole, 30 Amp, 120 VAC Coil Voltage
- Eaton offers a completely encased and compact design to protect the contactor from dust and other environmental elements.
- The universal mounting plate eliminates changing hole patterns when replacing competitive contactors.
- Equipped with binding head screws and quick connect terminals (side-by-side) for easy electrical connection.
- Eaton / Cutler Hammer contactors used in applications, other than HVAC, such as elevators, pools, food processing, pumps/compressors, lighting, hoists and cranes, battery chargers, printing presses, vending machines, and agriculture.
- UL Recognized, CSA certified, ARI 780 790 Standard, CE marked, RoHS Complaint.
Check Stock