Reviews High Resolution Thermocouple
Dry Block High Temperature Calibrator Range 50 to 650°C with Thermocouples T J K N R S for Calibration Labs Pharmaceutical Divisions Thermal Plants Metallurgical Plants Model AI-DBC-02
- Accuracy: ±0.025% of Reading + 0.25 mV | Volts Range: 0 to 10.000 V.
- Accuracy: ±0.025% of Reading + 3 mV | Ohms Range: 0 to 400 Ohms.
- Accuracy: ±0.025% of Reading + 0.1 Ohm | RTD3 Range: -200 to 8500 C.
- Thermocouple Types: T, J, K, N, R, S | Thermocouple Range( T,J,K,R,S): -200 to 400°C.
- Accuracy: ±0.025 % of Reading + 1°C |Thermocouple Range(R,S): 300 to 1760°C.
- Supply Scope: 1 Unit of DBC-02 Dry Block Calibrator, Power Cable, 1 Unit of Test Lead (2 Wire), Insertion Tube: Dual Hole - 1 x 1/4” + 1 x 12.5 mm, Dual Hole - 1 x 1/4” + 1 x 8.2 mm, 1 Unit of Insertion Tool, 2no.s of 6A Spare Fuses, Instruction Manual and Factory Calibration Certificate | Applications: Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants.
Check StockK-Type Scientific Digital Thermometer DM6801 with high Temperature thermocouple PK-1000
- Digital k-type thermometer with one input and extra thermocouple PK-1000.
- Temperature Range: -58.0 to 1999.0 °F (-50.0 to 1300.0 °C).
- Resolution: 0.1°F or °C or K Accuracy: 2.2° or 0.75% Data Hold.
- Comes with k-type thermocouple wire probe that measures up to 1832 degree fahrenheit (1000 degree Celsius).
- Battery: 9V (included!) Dimensions: 6" x 3" x 1.5" (149 x 71 x 41 mm) Weight: 7 oz (200 g).
Check StockPAPABA 50-550 Degree Fahrenheit BBQ Thermometer Gauge Stainless Steel Barbecue Grill Temperature Gauge BBQ Grill Smoker Heat Indicator Random
- 【Support K/J/T/E/R/S/N Type Thermocouples Measurement】Packed with two K-Type thermocouples, this Proster Digital Thermocouple can direct measure the temperature of tested object.
- 【Considerable Measuring Range】Can be used to measure the temperature of liquid / vapors and surface temperature of a solid object.Also suitable to be used both in the high temperature fields of blast furnance and cookery and the low temperature measuring for liquefied hydrogen and liquefied nitrogen etc.
- 【High Accuracy】K-type Thermocouple Measuring range: -50~300℃.
- Resolution: 0.1℃/℉<1000°,1.0℃/℉≥1000°.
- 【Functional Design】Data Hold Function.
- Double display with LCD Backlight shows T1/T2 and combination of T1 and T2.
- 【Wide Applications】Fish tank, pool, furnaces, ceramic, pottery, molten metal etc..
Check StockProster Digital Thermocouple Temperature Thermometer with Two K-Type Thermocouple Probe Backlight LCD K Type Thermometer Dual Channel for K/J/T/E/R/S/N Type
- 【Support K/J/T/E/R/S/N Type Thermocouples Measurement】Packed with two K-Type thermocouples, this Proster Digital Thermocouple can direct measure the temperature of tested object.
- 【Considerable Measuring Range】Can be used to measure the temperature of liquid / vapors and surface temperature of a solid object.Also suitable to be used both in the high temperature fields of blast furnance and cookery and the low temperature measuring for liquefied hydrogen and liquefied nitrogen etc.
- 【High Accuracy】K-type Thermocouple Measuring range: -50~300℃.
- Resolution: 0.1℃/℉<1000°,1.0℃/℉≥1000°.
- 【Functional Design】Data Hold Function.
- Double display with LCD Backlight shows T1/T2 and combination of T1 and T2.
- 【Wide Applications】Fish tank, pool, furnaces, ceramic, pottery, molten metal etc..
Check StockThermco ACC310DLSDIG Laboratory Long Stem Digital Thermometer, 12\ Stem Length, -50 to 300°C Range, +/-1.0°C Accuracy
- High Temperature K-type Thermocouple Thermometer Set with Stainless Steel Probe.
- K-type thermocouple wire with Standard Accuracy: +/- 2.2 °C or +/- .75%.
- 5 ft (155 cm) long thermocouple cable with braided stainless steel cover, mini thermocouple plug made from chromel / alumel.
- Temperature measurement range: -328 to 932 °F (-200 to 500 °C), short term 1472 °F (800 °C).
- Grounded K-type Thermocouple junction for fast measurements, 1x 9V battery included.
Check StockMulti Channels Digital Industrial Thermometer Temperature Data Logger (AT4716)
- Test range: -200 ° C ~ 1800 ° C Resolution: 0.1 ° C Accuracy: 0.2% ± 1.
- AT4808 handheld multi-channel temperature meter adopts high-performance ARM micro processor, can collect multi-channel temperature data simultaneously and response quickly..
- AT4808 has the function of checking broken thermocouple, high/low beep function and communication transmission. 128 channels temperature data can be extended, compatible with various temperature sensors. Equipped with Mini-USB (virtual series port) interface to realize data acquisition, analysis and print through the standard computer software. Support USD disk storage, real-time sampling data storage. The users can adjust data for each channel independently..
Check StockUNI-T UT701 Single Function Temperature Calibrator
- 1. Up to 0.05% output accuracy 2. 6-digit display 3. Output functions: DC voltage, resistance, thermocouple, and thermal resistance.
- 4. 10 thermocouple scales 5. 4 thermal resistance scales 6. High precision automatic cold junction compensation for thermocouple outputs.
- 7. Manual stepping and automatic stepping and ramping 8. Stores and recalls setups.
Check StockTraceable Water-Resistant Thermocouple Thermometer with Calibration
- Display Type: 0.625" Display, 3.75-digit LCD.
Check StockDigi-Sense Benchtop PID Temperature Controller, 1-Zone, Type J; 120 VAC
Check StockTECPEL DTM-305 Digital Single Input Thermocouple Thermometer with Type k thermocouple Probe (TPK-01)
- Measuring range : -50~1,300 °C (-58~2,000 °F).
Check StockDigi-Sense Traceable Remote-Monitoring Thermocouple Thermometer with Calibration; Celsius
Check StockTecpel DTM-319 Four Channel Type-K Thermocouple Data Logger Thermometer Taiwan-Made
- Measuring Range : -200~1370°C (-328~2,498°F).
- Accuracy : ±(0.3% + 1°C) at -200°C ~ 200°C.
- Accessory : Software program for Windows、USB cable、RS-232 Computer interface,TPK-01*4、Suitcase.
Check StockInrush Current Clamp Multimeter, BTMETER BT-570N TRMS 5999 Display Clamp-on Amp Meter for AC/DC Voltage Amperage Ohm Temperature Test
- ...1A amp resolution for 1000A. Ideal inrush clamp meter for troubleshoot electrical mechanical problem of cars motors boat HVAC household appliances safely and accurately..
- ✅LARGE DIGITAL DISPLAY - Well built with backlit LCD for visibility in dimly light areas. Extensible thermocouple probe support measures high temperature from -4 to 1832℉(-20 to 1000℃). Jaw Caliber Size 1.77 inches (45mm).
Check Stock